SHT2000 Temperature and Humidity Controller Operating Instructions
Product Name: Temperature and Humidity Controller Product Model: SHT2000
Supply voltage: AC 110~230V Power supply frequency: 50/60Hz
Temperature range: -20~60C Humidity range: 0%~100%RH
Temperature measurement accuracy: 0.3 C Humidity measurement accuracy: 3%
Output Control: Relay Output Output Power: MAX 10A
Setting method: Start value
Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode)
Heating/cooling mode setting:
Setting mode: setting (starting temperature): Press and hold the button to start the temperature flashing. Use key to set the starting temperature value.
Setting (stop temperature): Press and hold the button to stop the temperature flashing. Use to set the stop temperature value.
Heating use case: control the water heater, heat to 65 C to stop, the temperature drops back to 50 C and start heating again
Step 1: heating mode, starting temperature
Step 2: Press and hold the button to start the temperature flashing. Use to set the starting temperature to 50 C.
Step 3: Press and hold the button to stop the temperature flashing. Set the stop temperature to 65 C with keys, and the setting is completed!
Refrigeration use case: use in the farm, the fan is ventilated to 26 C to stop, the temperature is raised to 30 C and the ventilation is started again.
Step 1: cooling mode, starting temperature > stop temperature
Step 2: Press and hold the button to start the temperature flashing. Use to set the starting temperature to 30 C.
Step 3: Press and hold the button to stop the temperature flashing. Use to set the stop temperature to 26C. The setting is completed!
Humidification/Dehumidification Mode Settings:
Setting (start humidity): Press and hold key to start the humidity value flashing. Set the humidity value by key. Set [Stop Humidity]: Press and hold key to stop the humidity value flashing, and set the humidity to stop by key value.
Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification.
Setup steps:
Step 1: Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH.
Step 2: long press the button for 3 seconds to stop the humidity value flashing, set the value to 80% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.
Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification
Setup steps:
Step 1: Press and hold the button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40% RH.
Step 2: Press and hold the button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.